In case of a fire, temperature can reach up to 700°C in the first fifteen minutes and then can rise up to 1100°C. Product behaviour such as ignition, surface spread, smoking and dripping are critical when fighting the fire.
DuPont has carried out a series of fire performance testing at independent notified bodies including BRE Certification Ltd., United Kingdom and MFP Leipzig GmbH, Germany.
| Test method |
Description |
Product classification |
| BS EN ISO 11925-2 |
Surface and edge exposure, 30 s flame application time each |
Class E |
| BS 476 part 7 |
Method of test to determine the classification of the surface spread of flame of products; Energain® installed behind plasterboard, Energain® stand alone |
Class 1 |
| BS EN 13501-1:2003 |
Fire resistance testing. The results are classified: A1, A2, B, C, D, E and F. The norm considers not only how combustible products are, but also smoke and dripping behaviour. |
Class E |
Test reports are available upon request, please contact us.